Standard Setting Electrode (Type Matrix)

 Electrodes arrangement Sheet Top and Bottom Sheet
Arrange so that the top sheet and bottom sheet of high surface resistance, the ITO pattern was short.Being a low surface resistance, the ITO Parttern its length.In the normal length of ITO and ITO Bottom Pattern Pattern Short Top.

Position and Size of Electrodes
1.If the Heat Seal on Outer Electrode.His images like this:
① Electrode Width: Normal 2 ~ 3mm, Most Small 1mm. Make the pattern as thick as possible.But if there are processes at the electrode Through Hole, ≥ 2 mm.

② overlap Electrodes: 0.5mm Smaller than ITO pattern on one side.③ Position Electrodes: ≥ 0.5mm from viewing AREA, positioned outside.

2.If the Heat Seal Electrodes.His images like this:
① Electrode Width: ≥ 4mm. As much as possible keep the width.② Overlap Electrodes: smaller 0.5 mm from the ITO pattern on one side.③ Position Electrodes: ≥ 0.5 mm from viewing AREA, positioned outside.

④ Relations Position Ihosei and ITO: Normal: 1mm, Most small: 0.5mm.